OPERATING INSTRUCTIONS FOR GAMBIT EQUALIZER EQ1-LP TECHNICAL DATA
Daniel Weiss Engineering Ltd., Florastr. 42, CH-8610 Uster Page 26 of 28
+41 1 940 20 06 +41 1 940 22 14 http://www.weiss.ch [email protected]
Dump Remote Control
All System-Exklusive commands consist of a header, a message type, possible data and the EOS (end of sys-
tem exclusive). Below is the format of the header:
Byte Value Description Section
1
F0
Sysex
Header
2
00
Manufacturer's ID
3
30
M
anufacturer's ID
4
5A
Manufacturer's ID
5
06
Model ID: 6 = Gambit EQ
6
0000nnnn
Device ID:
-
> Midi channel number
Following is a list of the supported MIDI system exclusive commands (without header):
Snapshot format for dump. A complete dump consists of 128 snapshots:
Byte Value Description Section
1
-
6
...
...
Header
7
00000001
message = Snapshot dump
Message Type
8
0nnnnnnn
Package number ( 0..7F)
Data
9
0nnnnnnn
scale set number
10
-
265
0nnnnnnn
256 Bytes of Snapshot data
266
0ccccc
cc
Checksum without byte one (F0 Sysex Command)
Checksum
267
F7
EOS
EOS
Dump request:
Byte Value Description Section
1
-
6
...
...
Header
7
00000010
message = dump request
Message Type
8
F7
EOS
EOS
Version request:
Byte Value Description Section
1
-
6
...
...
Header
7
00000011
message = version request
Message Type
8
F7
EOS
EOS
Version send:
Byte Value Description Section
1
-
6
...
...
Header
7
00000100
message = send version
Message Type 4